Home » Neonatal and paediatric central venous catheters » Premicath – 1Fr / 28G
Premicath – 1Fr / 28G
Arterial Leadercast is a catheter for arterial access inserted by the Seldinger technique. Although it can be inserted in a variety of arteries, the most common sites for the placement of this catheter are the radial and the femoral artery.
About Product
- Introducer : breakaway needle, 24G short I.V. cannula, peelable cannula, no introducer
- Catheter markings every centimetre
- Fixation wings and integral extension tube to give comfortable fixation: length of extension tube (PUR) 8 cm
Codes 1261.102/152/153/206/207/302/306/307 have no fixation wings but a pink connector where the non-peelable plastic cannula can be attached.
- Premicath is supplied with or without stylet
Présented in a rigid blister pack containing:
- 1 PUR catheter (XRO)
- 1 introducer (except codes 1261.201/206/207)
- 1 measuring tape
Catheter | Introducer | Stylet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Prim. vol. ml |
Length cm |
Flow rate (Pressure 1 bar) ml/min |
Ø G |
Ext. Ø mm |
Pink hub | Fixation wings | Ext. Ø mm |
Length mm |
G | Type | – | |
1261.080 |
0.07 | 8 | 1.6 | 28 | 0.35 | No | Yes | 0.7 | 19 | 24 | Splitting needle | No | |
1261.102 |
0.08 | 10 | 1.4 | 28 | 0.35 | Yes | No | 0.7 | 19 | 24 | 24G short IV cannula | Yes | |
1261.152 |
0.08 | 15 | 0.9 | 28 | 0.35 | Yes | No | 0.7 | 19 | 24 | 24G short IV cannula | No | |
1261.153 |
0.08 | 15 | 0.9 | 28 | 0.35 | Yes | No | 0.7 | 19 | 24 | 24G short IV cannula | Yes | |
1261.20 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | 0.7 | 19 | 24 | Splitting needle | No | |
1261.201 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | – | – | – | Without introducer | No | |
1261.203 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | 0.7 | 19 | 24 | Splitting needle | Yes | |
1261.204 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | 0.9 | 20 | 22 | Neocath split | No | |
1261.205 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | 0.9 | 20 | 22 | Neocath Split | Yes | |
1261.206 |
0.09 | 20 | 0.7 | 28 | 0.35 | Yes | No | – | – | – | Without introducer | Yes | |
1261.207 |
0.09 | 20 | 0.7 | 28 | 0.35 | Yes | No | 0.7 | 19 | 24 | 24G short IV cannula | Yes | |
1261.208 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | 1.0 | 21 | 20 | Microflash | Yes | |
1261.21 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | 0.7 | 19 | 24 | Splitting needle | No | |
1261.210 |
0.09 | 20 | 0.7 | 28 | 0.35 | Yes | No | – | – | – | Without introducer | Yes | |
1261.22 |
0.09 | 20 | 0.7 | 28 | 0.35 | No | Yes | 1.0 | 21 | 20 | Microflash | No | |
1261.302 |
0.11 | 30 | 0.6 | 28 | 0.35 | Yes | No | 0.7 | 19 | 24 | 24G short IV cannula | No | |
1261.306 |
0.11 | 30 | 0.6 | 28 | 0.35 | Yes | No | – | – | – | Without introducer | Yes | |
1261.307 |
0.11 | 30 | 0.6 | 28 | 0.35 | Yes | No | 0.7 | 19 | 24 | 24G short IV cannula | Yes | |
1261.310 |
0.11 | 30 | 0.6 | 28 | 0.35 | Yes | No | – | – | – | Without introducer | Yes |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No
- Non-pyrogenic: Yes